Ultra-Inline Spill Deck®

Inline Model

Low profile, "in line" designs save valuable floor space and comply with spill containment regulations

Product Highlights

Ultra-Inline Spill Decks

Part # Model Dimensions in. (mm) Weight Capacity UDL (lbs) Containment Capacity gal. (L) Weight lbs. (kg) Quantity
23603-Drum Model77.9 x 25.9 x 5.8 (1978.2 x 657.4 x 146.1)4500 (2041.2)99 (374.8)67 (30.4)(1) 1-Drum Spill Deck module, (1) 2-Drum Spill Deck module, (1) Bladder Attachment, (1) Bulkhead Fitting, (1) T-Strip
23614-Drum Model104 x 25.9 x 5.8 (2641.6 x 657.4 x 146.1)6000 (2721.6)110 (416.4)84 (38.1)(2) 2-Drum Spill Deck modules, (1) Bladder Attachment, (1) Bulkhead Fitting, (1) T-Strip
23335-Drum Model129.9 x 25.9 x 5.8 (3299 x 657.4 x 146.1)7,500 (3,402)110 (416.4)107 (48.5)(1) 1-Drum Spill Deck module, (2) 2-Drum Spill Deck module, (1) Bladder Attachment, (2) Bulkhead Fittings, (2) T-Strips
23346-Drum Model156 x 25.9 x 5.8 (3962.4 x 657.4 x 146.1)9,000 (4,082)66 (249.8)132 (59.9)(3) 2-Drum Spill Deck module, (2) Bulkhead Fittings, (2) T-Strips
Swipe to scroll table

Options

Part # Model Product Image Dimensions in. (mm) Weight Capacity UDL (lbs) Containment Capacity gal. (L) Weight lbs. (kg)
1089Loading Ramp for P2 and P432 x 24 x 5.8 (812.8 x 609.6 x 146.1)600 (272)N/A17.0 (8.0)
2317Bladder Attachment25.9 x 4.6 x 4.6 (657.86 x 117.6 x 117.6)N/A66 (249.8)4 (1.8)
6340Replacement Bladder66 x 65.5 x 4.5 (1676.4 x 1663.7 x 114.3)N/A66 (249.8)2 (.9)
2345Bladder Pump12 x 7 x 5.5 (304.8 x 177.8 x 139.7)N/AN/A3 (1.4)
Swipe to scroll table

Frequently Asked Questions

No.  Spilled liquids will more than likely cause the internal surfaces of the bladder to adhere to each other.  We cannot guarantee the proper deployment of a reused bladder.

We recommend using a pump (UltraTech part# 2345 can be used) to remove any spilled contents from a sump or bladder.  (Note:  spillage should be pumped into an approved container).

The spill deck ramp (part# 1089) comes complete with two steel clips that quickly install on the end of the ramp.  These clips hook onto the connecting spill deck and keep the ramp from moving or shifting during loading or unloading. NOTE:  The ramp is not designed to be used with the P1 spill decks or the short side of the P2 spill decks.

Other than the spill deck, you’ll need one bulkhead fitting (part# 1073) and one t-strip (part# 1131) for every 26” of spill deck length that is connected.  For example, if you’re connecting a 4-drum spill deck to another 4-drum spill deck you would need two bulkhead fittings and two t-strips.  If, on the other hand, you were connecting a 1-drum spill deck to the short end of a 2-drum spill deck, you would only need one each of the bulkhead fitting and t-strip.

Yes, all grating surfaces on the spill decks are slip resistant.

The spill deck can NOT be moved with a forklift or pallet jack. The design of the spill deck sidewalls sometimes leads users to think that it is forkliftable or able to be moved with a pallet jack. But what may appear to be forklift pockets are actually supports for the grating.

The t-strips lay across the point where two spill decks come together.  By “bridging the gap” this piece diverts spills to either of the decks and keeps any spillage from getting between the units.

(Note:  The answer to this question is based on one assumption:  That the spill decks are being used with 55-gallon drums).  Yes, all of the Ultra-Spill Deck Inline Models meet EPA requirements.

All spill decks inline models use a grating that is 48″L x 24″W x 2.5″H or 24″L x 24″W x 2.5″H .

The replacement bladder (Part# 6340) is what you would need to order.  It is just the bladder and does not include the outer housing.  The bladder attachment (Part# 2317) includes a bladder and the outside housing.

The bladder will roll out 65.5″ away from the deck and will be 66″ wide when completely unfurled.

Helps Comply with These Rules & Regulations

  • EPA Container Storage Regulation 40 CFR 264.175
  • Spill Prevention, Control and Countermeasures Rule 40 CFR 12